Benvenuto sul sito di WEAP
WEAP
WEAP è una iniziativa dell' Stockholm Environment Institute.


A proposito di WEAP

Pagina iniziale
Perchè WEAP?
Caratteristiche
Cosa c'è di nuovo
Schermata esemplificativa
Dimostrazione
Applicazioni
Pubblicazioni
Storia e testimonianze

Usare WEAP
Scarica
Licenza
Manuale
Esempi
Video
Risorse

Forum degli utenti
Discussioni
Lista dei membri
Crea il tuo profilo

Ulteriore supporto
Formazione
Corsi universitari
Collaborazioni

Chi siamo
Programma SEI-US sulle risorse idriche
Contatti

 Notizie sull'Ambiente
LEAP Ti interessa l'Energia?
Informati a proposito di LEAP: Software SEI sulla pianificazione energetica

Forum degli utenti

All Topics | Topic "Setting Supply"
Log in to post new messages or reply to existing messages.
 
Author Messaggio
Janak Timilsena

Subject: Setting Supply   
Posted: 12/10/2009 Viewed: 11655 times
I have reservoir, streamflow, groundwater and desalination water as sources. I have a single demand. I would like to set the reservoir to be stored(i.e. no supply from the reservoir) during the some time of the timesteps(wet period of a year), and utlized it during another time steps.

Basically, I would like to supply water only from the groundwater, streamflow and desalination water when the reservoir is not in use. But some other timesteps, I would like to set the reservoir supply as the preferred supply of water, so that the stress on the other water uses can be reduced. Do you have any suggestion to model this thoughts?
Jack Sieber

Subject: Re: Setting Supply   
Posted: 12/10/2009 Viewed: 11654 times
I suggest setting the Supply Preference to 1 for the reservoir, and set to 2 for the groundwater, streamflow and desalination (or you could order these 2, 3 and 4 if you want), and then setting a flow restriction on the transmission link that connects the reservoir to the demand, so that the maximum flow is 0% of demand when the reservoir is not in use (which will force WEAP to use the other sources), and 100% of demand when the reservoir is in use.

Jack